How to Reduce COD in ETP: Causes and Treatment Solutions

Overview
High COD in ETP means the wastewater contains substances that need oxygen to be chemically oxidised.
Common causes include high organic loading, chemicals, oils, poor aeration and substances that microorganisms cannot easily break down.
How to reduce COD in ETP depends on whether the pollutants are biodegradable, suspended or dissolved.
Biological treatment removes biodegradable organic matter, while chemical and physical methods can treat other pollutants.
COD levels may remain high even when the aeration tank is working properly.
Regular inlet and outlet testing helps operators find where treatment is failing.
Table of Contents
Introduction
To reduce COD in an ETP, first check what is causing the high reading. Then select a treatment method based on the pollutants present. Biological treatment works for biodegradable organic matter, while chemical treatment may be needed for substances that bacteria cannot easily break down.
For example, a food-processing ETP may show high COD because of fats and organic waste. A textile ETP may have high COD because of dyes and other chemicals.
Using the same treatment method for both may not give the expected results.
Understanding how to reduce COD in ETP starts with checking the wastewater, not simply increasing aeration or adding more chemicals.
What Is COD in Wastewater Treatment?
COD stands for Chemical Oxygen Demand.
It measures the amount of oxygen needed to chemically oxidise substances present in wastewater under standard test conditions.
COD is usually measured in milligrams per litre (mg/L).
A high COD reading means the wastewater contains a greater amount of chemically oxidisable material.
However, COD does not tell operators exactly which pollutants are present or whether bacteria can remove them.
What happens if COD is high in wastewater?
High COD can indicate a high pollution load. If untreated wastewater enters a river or lake, biodegradable pollutants may consume dissolved oxygen as they break down.
High COD may also mean the treated effluent does not meet its permitted discharge limit.
What Causes High COD in ETP?
The causes of high COD in ETP depend on the industry and wastewater composition.
Cause | How it affects COD |
High organic loading | More biodegradable waste enters the plant |
Oils and grease | Add organic pollutants that may be difficult to treat |
Industrial chemicals | Some substances resist biological breakdown |
Low dissolved oxygen | Limits aerobic biological treatment |
Toxic substances | Can inhibit microorganisms |
Poor settling | Organic solids may escape with treated water |
Sudden wastewater discharge | Can exceed the treatment capacity |
High COD in industrial effluent is common in food processing, dairy, textile, pharmaceutical and chemical manufacturing.
Each industry may need a different treatment approach.
1. Check the COD and BOD Before Choosing a Treatment
COD and BOD help operators understand wastewater characteristics.
BOD measures the oxygen used by microorganisms to break down biodegradable organic matter during a specified test period.
COD measures chemically oxidisable substances.
The BOD-to-COD ratio can give an initial indication of how suitable the wastewater may be for biological treatment.
For example, wastewater with a relatively high BOD-to-COD ratio may respond well to biological treatment.
A low ratio may indicate poorly biodegradable substances, although further testing is needed.
2. Improve Biological COD Removal in the Aeration Tank
Biological COD removal uses microorganisms to break down biodegradable organic pollutants.
If the COD is not reducing in ETP aeration tank operations, check the conditions needed for microbial activity.
What should operators check?
Dissolved oxygen: Check whether the aeration system supplies enough oxygen.
pH: Confirm that the wastewater is suitable for the microorganisms present.
MLSS and sludge age: Check whether enough active biomass remains in the reactor.
Organic loading: Compare incoming COD with the plant's treatment capacity.
Toxic chemicals: Check whether industrial discharges are affecting the bacteria.
Increasing aeration may help when oxygen is low. But extra air will not remove pollutants that microorganisms cannot break down.
3. Use Chemical Treatment for COD Reduction
Chemical treatment for COD reduction may be needed when biological treatment alone cannot remove certain pollutants.
Common methods include:
Coagulation and flocculation: Chemicals help suspended and colloidal particles join into larger flocs that can be separated.
Chemical oxidation: Selected oxidising agents react with certain dissolved organic pollutants.
Fenton treatment: Iron salts and hydrogen peroxide are used under controlled conditions to oxidise some difficult organic compounds.
Chemical treatment does not remove every type of COD. The choice should follow wastewater testing and, where needed, laboratory trials.
Chemical dosing can also increase treatment costs and sludge production.
4. Remove Oils, Grease and Suspended Solids Before Biological Treatment
Oils and suspended organic solids can increase COD loading.
If these pollutants enter the aeration tank in large amounts, they may affect oxygen transfer and biological treatment.
How to reduce COD in industrial wastewater before aeration
Use grease traps where suitable.
Consider dissolved air flotation for wastewater containing oils and suspended particles.
Remove settleable solids through primary treatment.
Prevent concentrated waste streams from entering the ETP without control.
These steps reduce the load entering biological treatment, although they may not remove dissolved COD.
5. Control Sudden Changes in Industrial Wastewater
An ETP may work well during normal production but struggle after equipment cleaning or a sudden industrial discharge.
This happens when wastewater strength changes faster than the treatment system can respond.
An equalisation tank can help mix wastewater and reduce sudden changes in flow and pollutant concentration.
Operators should also record when high-strength wastewater enters the plant.
This makes it easier to connect COD increases with specific production activities.
Why Is COD High After Biological Treatment?
COD may remain high after biological treatment even when microorganisms are active.
Possible reasons include:
Non-biodegradable dissolved organic substances.
Incomplete breakdown of biodegradable pollutants.
Poor sludge settling.
Toxic substances affecting bacteria.
Insufficient treatment time.
Compare COD before and after each treatment stage.
If BOD has fallen but COD remains high, some remaining pollutants may be difficult to treat biologically.
Further testing can help identify whether chemical oxidation, adsorption or another treatment step is suitable.
COD Reduction in ETP: Troubleshooting Table
Observation | What to check first |
High inlet COD | Production discharge and equalisation |
High COD with low oxygen | Aeration system and organic loading |
High COD after biological treatment | Biodegradability and toxic substances |
High COD with cloudy outlet water | Sludge settling and suspended solids |
Sudden COD increase | Cleaning chemicals or process discharge |
COD remains high after chemical dosing | Chemical selection, pH and dose |
For operators asking how to improve COD removal efficiency in ETP, testing at different stages is more useful than changing every treatment setting at once.
Can Bioculture Help Reduce COD in ETP?
Bioculture contains microorganisms intended for biological wastewater treatment.
Amalgam Biotech offers bioculture products for wastewater treatment that may be considered for suitable industrial wastewater applications.
Bioaugmentation may help in some biological treatment systems, depending on wastewater characteristics and operating conditions.
However, adding microorganisms cannot remove non-biodegradable chemicals or correct faulty aeration equipment by itself.
Conclusion
Understanding how to reduce COD in ETP requires identifying the pollutants responsible for the high reading.
Biological treatment can remove biodegradable organic matter. Chemical and physical treatment may be needed for other contaminants.
For reliable COD removal in effluent treatment plant operations, start with wastewater testing, check each treatment stage and correct the actual cause before changing the process.
Frequently Asked Questions
1. How to Reduce COD in Wastewater?
Identify whether the COD comes from biodegradable organic matter, suspended solids or difficult-to-treat chemicals. Then choose biological, physical or chemical treatment accordingly.
2. How to Reduce High COD in an Effluent Treatment Plant?
Check inlet COD, dissolved oxygen, pH, sludge age and treatment loading. Remove oils and solids where needed, and test whether additional treatment is required.
3. Which Treatment Method Is Best for High COD Wastewater?
There is no single best method. Biological treatment suits biodegradable organic matter, while chemical oxidation or other methods may be needed for certain industrial pollutants.
4. How to Reduce COD in Industrial Effluent Before Discharge?
Measure COD after each treatment stage. Correct biological treatment problems and add suitable further treatment if the remaining COD exceeds the permitted discharge limit.
5. Why Is COD Not Reducing in an ETP Aeration Tank?
Possible causes include low oxygen, toxic substances, excessive loading, insufficient active biomass or pollutants that microorganisms cannot readily break down.
Improve COD Removal with the Right Biological Treatment Support
Struggling with high COD levels in your ETP? Amalgam Biotech's BactaServe bioculture solutions support microbial activity and biodegradable organic matter removal under suitable operating conditions. Find the right biological treatment support for your industrial wastewater challenges.
.webp)