top of page

How to Reduce Ammonia in Wastewater Treatment: Causes and Solutions

Nov 16
5 min read
How to reduce ammonia in wastewater treatment using biological treatment processes in an industrial wastewater treatment plant.

Overview


  • A treatment plant may remove BOD and COD but still have high ammonia in wastewater effluent. This often means the biological nitrogen treatment needs attention.

  • Understanding how to reduce ammonia in wastewater treatment starts with checking dissolved oxygen, pH, alkalinity and sludge retention time (SRT).

  • Ammonia enters wastewater through urine, food waste, proteins and certain industrial chemicals.

  • Biological ammonia removal uses nitrifying bacteria to convert ammonia into nitrate under aerobic conditions.

  • Low oxygen, insufficient alkalinity, toxic chemicals and sudden ammonia loading can affect nitrification.

  • Ammonia removal from wastewater may also require air stripping or ion exchange when biological treatment is unsuitable.


Table of Contents


Introduction


The aeration tank is working, the treated water looks clear, and BOD levels are within the discharge limit. But the laboratory report shows ammonia nitrogen at 18 mg/L when the permitted limit is 5 mg/L.


Why is ammonia still present?


Bacteria that remove organic matter are different from those responsible for nitrification. A plant may remove BOD properly while ammonia remains untreated.


Understanding how to reduce ammonia in wastewater treatment means finding what is affecting nitrification before changing aeration or chemical dosing.


What Causes High Ammonia in Wastewater Effluent?


Ammonia comes from sewage, protein breakdown and industrial wastewater. It can also form when organic nitrogen breaks down inside the treatment plant.

Cause

Effect on ammonia removal

Low dissolved oxygen

Slows ammonia oxidation

Low alkalinity

Causes pH to fall during nitrification

Short sludge retention time

Nitrifying bacteria may be washed out

Toxic industrial chemicals

Can inhibit nitrifying microorganisms

Low temperature

Slows biological activity

Sudden ammonia loading

May exceed the reactor's treatment capacity

Check ammonia, nitrite and nitrate concentrations together. These readings help identify whether nitrification is occurring.


1. Improve Nitrification in Wastewater Treatment


Nitrification converts ammonia into nitrate through two biological steps:


  1. Ammonia-oxidising microorganisms convert ammonia into nitrite.

  2. Nitrite-oxidising microorganisms convert nitrite into nitrate.


Nitrifying bacteria reproduce more slowly than many bacteria responsible for BOD removal. They need enough oxygen and time inside the reactor.


For ammoniacal nitrogen removal, check SRT, dissolved oxygen and incoming ammonia loading before changing the process.


2. Maintain Enough Dissolved Oxygen


Nitrifying bacteria require oxygen to convert ammonia into nitrate.


Many activated sludge plants use approximately 2 mg/L dissolved oxygen as an initial operating reference, although the actual requirement depends on plant conditions.


What should operators check?


  • Measure oxygen at different locations in the aeration tank.

  • Inspect diffusers for blockages.

  • Check oxygen levels during high wastewater loading.

  • Compare ammonia concentrations before and after aeration.


Increasing aeration may help when oxygen is insufficient. But it will not correct problems caused by low alkalinity or toxic chemicals.


3. Check pH and Alkalinity


Nitrification consumes alkalinity, which helps wastewater resist changes in pH.


For every 1 mg of ammonia nitrogen converted to nitrate, approximately 7.14 mg of alkalinity, measured as CaCO₃, is consumed.


If alkalinity becomes too low, pH may fall and nitrification can slow down.


How to correct low alkalinity


  • Measure pH and alkalinity regularly.

  • Compare incoming alkalinity with the amount needed for nitrification.

  • Check whether pH falls across the aeration tank.

  • Add an appropriate alkalinity source, such as sodium bicarbonate, when testing shows it is needed.


Nitrification commonly works well around pH 7.0–8.5, depending on the treatment conditions.


4. Maintain Suitable Sludge Retention Time


SRT tells operators how long biological solids remain in the treatment system.


When sludge is removed too quickly, nitrifying bacteria may not reproduce fast enough to maintain their population.


This is one reason ammonia can remain high even when BOD removal is satisfactory.


Check MLSS, sludge wasting rates and clarifier settling before increasing SRT. The required sludge age depends on wastewater temperature and loading.


5. Use Denitrification When Total Nitrogen Must Be Removed


Nitrification converts ammonia into nitrate, but most of the nitrogen remains in the water.


Denitrification in wastewater treatment converts nitrate into nitrogen gas under anoxic conditions.

Process

What happens

Nitrification

Converts ammonia into nitrate using oxygen

Denitrification

Converts nitrate into nitrogen gas under anoxic conditions

Biological nitrogen removal may require both processes when the plant has a total nitrogen discharge limit.


6. Check Industrial Chemicals Affecting Ammonia Removal


Ammonia removal in ETP systems can become difficult when wastewater contains substances that inhibit nitrifying bacteria.


Heavy metals, certain solvents and high salt concentrations may interfere with biological treatment.


Operators should check whether ammonia increases after particular manufacturing activities.


Equalisation can help reduce sudden changes in loading, but it does not remove toxic substances.


Bioculture products, including Amalgam Biotech's BactaServe bioculture range, may be considered for suitable biological treatment applications. However, adding microorganisms does not automatically correct poor nitrification.


7. Consider Other Ammonia Removal Methods


Biological treatment may not suit wastewater containing very high ammonia concentrations or substances that prevent nitrification.

Method

How it works

Air stripping

Transfers ammonia from wastewater into an air stream under suitable pH conditions

Ion exchange

Uses exchange materials to remove ammonium ions

Membrane treatment

Certain membranes separate ammonium or other nitrogen compounds

Each method has different chemical, operating and waste-handling requirements.


How to Reduce Ammonia Levels in an STP or ETP


Before changing treatment settings, check these measurements:

Observation

What to investigate

High ammonia and low oxygen

Aeration and diffuser condition

High ammonia and falling pH

Alkalinity consumption

High ammonia after sludge wasting

Sludge retention time

High ammonia with rising nitrite

Incomplete nitrification

High ammonia after industrial discharge

Toxicity or sudden nitrogen loading

These checks help operators decide how to treat high ammonia in wastewater without making unnecessary changes.


Conclusion


Understanding how to reduce ammonia in wastewater treatment requires checking the conditions that support nitrifying bacteria.


Oxygen, alkalinity, sludge age and wastewater composition all affect ammonia nitrogen removal in wastewater treatment.


Start with laboratory results and operating records. The correct treatment depends on what is preventing ammonia conversion and the discharge standards the plant must meet.



Frequently Asked Questions


1. How Is Ammonia Removed from Wastewater?

Ammonia is commonly converted into nitrate through biological nitrification. Other methods include air stripping and ion exchange.


Common causes include low oxygen, insufficient alkalinity, short sludge age, toxic chemicals and sudden increases in ammonia loading.


Check dissolved oxygen, pH, alkalinity and SRT. Correct the condition affecting nitrifying bacteria before changing treatment chemicals.


Maintain suitable oxygen levels and sludge age. Monitor ammonia, nitrite and nitrate to check whether biological treatment is working.


Biological treatment can reduce ammonia to low concentrations under suitable conditions, but results depend on loading, temperature, reactor design and operating conditions.


Improve Ammonia Removal with Better Biological Treatment


High ammonia levels in wastewater can indicate problems with nitrification, oxygen availability or sludge retention time. Amalgam Biotech's BactaServe Bioculture range supports suitable biological treatment applications. Identify the factors affecting your ammonia removal process and improve treatment performance while maintaining discharge compliance.




 
 
bottom of page