Sewage Treatment Plant Problems and Solutions: Common Causes and How to Fix Them

Overview
Common sewage treatment plant problems include poor BOD removal, sludge bulking, bad odour, excessive foam, high MLSS and cloudy treated water.
Most STP problems are linked to low dissolved oxygen, unsuitable sludge age, sudden changes in sewage flow or poor biological activity.
Black water in an STP may indicate septic conditions caused by a lack of oxygen, although colour alone cannot confirm the cause.
Sludge that does not settle properly can escape into the treated water, increasing suspended solids and affecting discharge quality.
Regular checks of dissolved oxygen, MLSS, pH, sludge settling and BOD help operators identify problems before changing the treatment process.
This guide covers sewage treatment plant problems and solutions, including what causes each issue and what operators should check first.
Table of Contents
Introduction
The most common sewage treatment plant problems are poor BOD removal, sludge that refuses to settle, bad smells, excessive foaming and cloudy outlet water. These problems usually point to changes in oxygen supply, microbial activity, sludge wasting or incoming sewage quality.
For example, an STP may have working aerators but still produce water with high BOD. Another plant may have clear water in the aeration tank but lose sludge through the secondary clarifier.
Understanding sewage treatment plant problems and solutions starts with checking what is happening inside the plant rather than adding chemicals or increasing aeration without testing.
1. Poor BOD Removal in Sewage Treatment Plants
Poor BOD removal means the STP is not removing enough biodegradable organic matter before discharge.
Common causes
Low dissolved oxygen in the aeration tank.
Excessive incoming organic loading.
Insufficient active biomass.
Toxic substances affecting microorganisms.
Short hydraulic retention time.
How to fix poor BOD removal
First, check dissolved oxygen in STP aeration tanks. Many conventional activated sludge plants operate around 1–3 mg/L DO, although the required level depends on plant design.
Next, compare inlet and outlet BOD results. Check MLSS and sludge wasting records to see whether enough active biomass is present.
If incoming sewage strength has increased, review the loading against the plant's treatment capacity.
2. Sludge Bulking and Poor Settling in STP
Sludge bulking occurs when activated sludge settles poorly in the secondary clarifier.
This can cause suspended solids to escape with the treated water.
Why is sludge not settling in STP?
Common reasons include:
Excessive filamentous bacterial activity.
Low dissolved oxygen.
Unsuitable food-to-microorganism ratio.
Nutrient imbalance.
Changes in sludge retention time.
How to solve sludge settling problems
Measure the sludge volume index (SVI) and check the sludge blanket depth.
If filamentous bulking is suspected, examine the sludge under a microscope where testing is available.
Correct the operating condition causing poor settling. Increasing sludge wasting without checking SRT may make the problem worse.
3. Sewage Treatment Plant Odour Problems
A strong rotten-egg smell near an STP often indicates hydrogen sulphide formation under low-oxygen conditions.
This may happen in collection tanks, sludge holding tanks or stagnant sections of the plant.
Common causes
Sewage remaining stagnant for long periods.
Septic conditions in collection tanks.
Accumulated sludge.
Poor ventilation or inadequate mixing.
How to reduce STP odour
Check where the smell starts. Remove accumulated sludge where necessary and prevent sewage from remaining stagnant.
Review mixing, oxygen conditions and sludge handling practices.
Hydrogen sulphide can be dangerous at high concentrations. Staff should follow gas monitoring and confined-space safety procedures rather than entering tanks to investigate odour.
4. High MLSS in STP Aeration Tanks
Mixed liquor suspended solids (MLSS) measures the concentration of suspended solids in the biological reactor.
High MLSS in STP systems is not always a problem, but excessive concentrations can affect oxygen transfer and clarifier loading.
Why does MLSS increase?
Insufficient waste sludge removal.
Changes in organic loading.
Longer sludge retention time.
Accumulation of inert solids.
How to control high MLSS
Check MLSS, SRT and the waste activated sludge rate together.
If solids are accumulating, adjust sludge wasting gradually while monitoring BOD removal and settling.
Do not reduce MLSS simply to reach a fixed number. The suitable range depends on the STP design and operating conditions.
5. Scum and Foaming in the Aeration Tank
Foam is common during biological treatment, but persistent or thick foam may indicate an operating problem.
What causes foaming?
Surfactants and detergents entering sewage.
Young sludge during plant start-up.
Filamentous microorganisms.
Changes in organic loading.
How to reduce foam in STP
First, check whether the foam is temporary or persistent.
White, light foam may occur during start-up or when surfactants enter the plant. Thick, stable brown foam can sometimes be associated with certain filamentous organisms.
Check sludge age, incoming sewage and biological conditions before using antifoaming chemicals.
6. Why Does STP Water Turn Black?
Black sewage or mixed liquor may indicate oxygen-depleted conditions.
When wastewater remains without enough oxygen, anaerobic reactions can produce sulphides. These may react with metals and darken the water.
How to correct black water
Check dissolved oxygen and mixing.
Inspect aerators and air supply.
Remove stagnant sludge deposits.
Review sewage retention time in collection tanks.
Check whether industrial wastewater has entered the STP.
Colour alone cannot identify the exact cause. Testing is needed before changing treatment settings.
7. Cloudy or Dirty Treated Water
Cloudy outlet water often means suspended solids are passing through the final settling tank.
This may happen because of sludge bulking, excessive hydraulic flow or poor clarifier operation.
What should operators check?
Check the sludge blanket, SVI, return activated sludge rate and outlet suspended solids.
If sludge is escaping during peak flow, review whether the clarifier is receiving more water or solids than it can handle.
The correct action depends on whether the problem comes from biological settling or hydraulic loading.
Sewage Treatment Plant Troubleshooting Checklist
For operators wondering how to fix STP problems, the following checks can help identify the likely cause.
STP problem | First thing to check |
High outlet BOD | DO, organic loading and active biomass |
Sludge not settling | SVI, filamentous organisms and sludge age |
Rotten-egg smell | Septic zones and accumulated sludge |
High MLSS | SRT and sludge wasting |
Excessive foam | Surfactants, sludge age and filamentous organisms |
Black wastewater | Oxygen supply, mixing and septic conditions |
Cloudy treated water | Clarifier settling and hydraulic loading |
Can Bioculture Help With STP Problems?
Bioculture products contain microorganisms intended for biological wastewater treatment.
For example, BactaServe STP from Amalgam Biotech is intended for sewage treatment applications.
Such products may be considered where biological treatment needs support. However, adding bioculture cannot correct faulty aerators, excessive hydraulic loading or poor sludge wasting by itself.
Plant operators should first identify the cause and check whether the selected microbial product is suitable for the treatment system.
Conclusion
Most sewage treatment plant problems and solutions involve checking oxygen supply, sludge settling, biological activity and incoming sewage conditions.
Poor BOD removal, sludge bulking, odour and foaming may look like separate sewage treatment plant issues, but some share the same underlying causes.
Regular monitoring helps operators find problems early and make changes based on actual plant conditions.
Frequently Asked Questions
1. What Are the Common Problems in Sewage Treatment Plants?
Common problems include poor BOD removal, sludge bulking, excessive foaming, bad odour, high MLSS and cloudy treated water. Their causes depend on biological conditions and plant operation.
2. Why Is My Sewage Treatment Plant Not Working Properly?
Check dissolved oxygen, MLSS, sludge age, incoming sewage load and clarifier settling. Equipment faults or sudden changes in wastewater can also affect treatment.
3. How to Solve Sewage Treatment Plant Problems?
Start by identifying the affected treatment stage. Test the relevant operating parameters, find the likely cause and make gradual corrections while checking outlet water quality.
4. How to Improve Sewage Treatment Plant Performance?
Maintain suitable oxygen levels, control sludge wasting, remove accumulated solids and check the incoming sewage load. Regular laboratory testing helps confirm whether treatment is working.
5. Can STP Problems Be Solved Without Adding Chemicals?
Many biological and mechanical problems can be corrected through better aeration, sludge control or equipment maintenance. Chemical treatment may still be necessary for certain pollutants or specific plant conditions.
Resolve Common STP Problems with Better Biological Treatment
Poor BOD removal, sludge bulking and unstable biological activity can affect sewage treatment plant performance. Amalgam Biotech's BactaServe STP supports biological treatment in sewage treatment systems under suitable operating conditions. Identify the right biological support for your STP and improve treatment performance.
.webp)